Luoyang Anjing Intelligence Equipment は高温電気炉の世界的リーダーです

Professional Fire Assay Crucible for Laboratory Gold Testing and Analysis
製品パラメータ
Main composition: Bone ash or magnesium oxide (MgO)
Characteristics: Highly absorbent porous structure; good refractoriness and oxidation resistance
Bone ash cupel: Excellent absorption performance
Magnesia cupel: More stable structure, higher mechanical strength, suitable for batch production analysis
Recommended service temperature: 900°C – 1050°C
Typical process temperature: Approximately 950°C (varies slightly depending on lead content and furnace type)
説明
Fire Assay Cupel and Crucible
Fire assay ash dishes are refractory consumables used in the fire assay process for precious metal analysis, primarily in the ash blowing stage. They adsorb molten lead and lead oxide, allowing gold and silver to accumulate on the surface of the ash dish for easy subsequent weighing or content determination.They are generally used in conjunction with fire assay clay crucibles. They offer excellent lead adsorption under high-temperature oxidation conditions, are heat-resistant, and chemically stable, making them a common consumable in ore analysis, precious metal testing, and metallurgical laboratories.
製品の特徴
- High-Quality Materials, High Absorption Performance
Made primarily from bone ash or magnesium oxide (MgO), these dishes are pressed and sintered. Bone ash dishes possess excellent absorption performance; magnesium oxide dishes have a more stable structure and higher mechanical strength, suitable for batch production analysis. High chemical purity ensures extremely low background interference from precious metals in fire assay analysis.
- Porous Structure, Uniform Absorption Rate
The highly absorbent porous structure with uniform pore distribution ensures consistent absorption rates. It can rapidly absorb large amounts of PbO (lead oxide), leaving precious metals on the surface of the dish to form gold and silver particles, without causing the pores to crack due to excessive absorption.
- Good Refractoriness, High-Temperature Structural Stability
Recommended operating temperature: 900-1050℃, typical process temperature: around 950℃ (slight variations depending on lead content and furnace type). It can withstand prolonged operation under high-temperature oxidation conditions without softening or collapsing, ensuring the complete ash blowing process.
- Strong affinity for oxygen, resulting in high separation efficiency
It possesses excellent affinity for oxygen, promoting the oxidation reaction of lead and improving the separation efficiency between precious metals and lead. After lead is oxidized to PbO, it is absorbed by the ash dish, while gold and silver remain in the center of the dish, forming metal particles that can be used for subsequent weighing and composition analysis.

| 1. Pre-use treatment | The cupel should be dried or preheated at low temperature before use to avoid cracking due to moisture. |
| 2. Heating procedure | After loading lead-containing particles, slowly raise the temperature according to the process curve to the cupellation temperature. |
| 3. Process phenomenon | After the cupel absorbs lead, a distinct “white core” or “halo” will appear, which is a normal phenomenon. |
| 4. Result determination | After absorption is complete, gold and silver particles will remain in the center of the cupel and can be used for subsequent evaluation. |
| 5. Reuse | The cupel is not reusable and should be replaced according to the experimental procedure. |
応用分野
- Precious Metal Content Detection: Used for quantitative fire assay analysis of precious metals such as gold, 銀, 白金, and palladium. The ash dishes absorb lead and its oxides during the ash blowing step, enriching the precious metals on the surface; this is a key consumable for accurate fire assay analysis.
- Mining and Metallurgical Laboratories: Suitable for fire assay analysis of precious metal components in geological samples such as ores, 濃縮物, 尾鉱と尾鉱. The ash dishes are used in conjunction with fire assay clay crucibles to complete the entire analytical process of melting-ash blowing-weighing.
- Alloy Material Composition Analysis: Used for the detection and analysis of precious metal components in alloy materials, providing reliable data for material quality control.
- Research Institute Experiments: Suitable for high-temperature oxidation absorption experiments and fire assay analysis research in geology, 冶金, materials science, and other related fields.
- Third-Party Testing Institutions: Suitable for various testing institutions conducting precious metal composition analysis services; the consistency and reliability of the ash dishes ensure the accuracy of the test results.
会社概要
熱処理技術サービスとRを専門とする専門企業&D, 製造業, 高温電気炉の販売.
同社は-100℃から2600℃までの全温度範囲をカバーする高温電気炉の開発に注力しています。. 実験用電気炉などの製品を展開, 真空雰囲気炉, 工業用窯, 中周波誘導加熱装置. 主な製品にはボックス炉などがあります。, 管状炉, 昇降炉, プッシャーキルン, 台車炉, ロータリーキルン, トンネル窯, 各種専用中周波炉.
同社は技術革新を堅持しており、ISO9001およびEU CE認証を取得しています。. それは所有しています 21 登録商標, 29 特許, そして 27 ソフトウェアの著作権.






お支払い方法
TT
発送方法
電気炉は3層でパッケージ化されています: まずは発泡紙で包みます, その後プラスチックフィルムで包みます, そして最後に木箱に詰めていきます.
よくある質問 (よくある質問)
- What is the main function of fire assay ash dishes?
Ash dishes are mainly used in the fire assay ash blowing process. By absorbing molten lead and lead oxide (PbO), they enrich precious metals such as gold and silver, thereby achieving the separation and detection of precious metals.
- What materials are commonly used to manufacture ash dishes?
Common materials include: Bone ash: excellent absorption performance, widely used in traditional fire assays; Magnesium oxide (MgO): higher mechanical strength, suitable for large-scale production and long-term storage.
- At what temperatures are ash dishes suitable for use?
The recommended operating temperature range is 900℃~1050℃. The actual ash blowing temperature is usually controlled at around 950℃. The specific temperature needs to be adjusted according to the sample composition and furnace type.
- Can ash dishes be reused?
Reuse is not recommended. During the ash blowing process, the ash dish absorbs PbO and undergoes structural changes. Reuse may affect the absorption performance and the accuracy of the detection results.
- What equipment are ash dishes suitable for?
Ash dishes are mainly used in conjunction with equipment such as fire assay furnaces, muffle furnaces, and high-temperature experimental furnaces for precious metal testing and metallurgical analysis experiments.